Greater muscle electrode distance and fat mass affect motor units identification from high-density surface EMG in the vastus lateralis muscle

Articolo
Data di Pubblicazione:
2025
Abstract:
Decomposing high-density surface electromyography (HDsEMG) signals enables non-invasive identification of motor units (MU); however, anatomical factors contribute to variability in the identified MU number across individuals. This study examined the influence of fat mass (FM%), muscle-electrode distance (MED), and muscle size on MU identification in the vastus lateralis. Thirty-three young (19-30 years) and twenty-eight older adults (66-82 years), including both sexes, performed isometric knee extensions at 15%, 35%, 50%, and 70% of maximal voluntary force (MVF) while HDsEMG signals were recorded. Whole-body and regional FM% were assessed using bioelectrical impedance analysis (BIA) and dual-energy X-ray absorptiometry (DXA), while MED and muscle size were measured with ultrasonography. Females exhibited greater MED and FM%, resulting in fewer identified MU than males. Significant negative correlations were found between the identified MU number and whole-body FM% (15%-70% MVF: BIA: r(s)=-0.508 to r(s)=-0.415; DXA: r(s)=-0.531 to r(s)=-0.337), leg FM% (15%-70% MVF: r(s)=-0.579 to r(s)=-0.582), thigh FM% (15%-70% MVF: r(s)=-0.614 to r(s)=-0.620), and MED (15%-70% MVF: r(s)=-0.581 to r(s)=-0.670). Notably, segmented regression analysis revealed a threshold at similar to 0.7 cm MED, below which a greater number of MU could be identified. Our findings highlight the negative impact of high FM% and MED on MU identification from HDsEMG decomposition.
Tipologia CRIS:
01.01 - Articolo in rivista
Keywords:
Decomposition; Electromyography; Motor unit; Muscle-electrode distance; Subcutaneous fat; Volume conductor
Elenco autori:
Sampieri, A.; Spinello, G.; Franchi, M. V.; Campa, F.; Paoli, A.; Moro, T.; Casolo, A.
Autori di Ateneo:
CAMPA FRANCESCO
CASOLO ANDREA
FRANCHI MARTINO
MORO TATIANA
PAOLI ANTONIO
SPINELLO GIOI
Link alla scheda completa:
https://www.research.unipd.it/handle/11577/3573679
Link al Full Text:
https://www.research.unipd.it//retrieve/handle/11577/3573679/1315034/Sampieri_et_al-2025-Scientific_Reports.pdf
Pubblicato in:
SCIENTIFIC REPORTS
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0